Original Research
Volume 2022, Article ID 22091315, 8 pages.
Quantitative analysis of apically extruded debris between selective rotary and reciprocating files by lyophilization & micro-balance
Ganesan Kayalvizhimeena L 1 , Shanmugam Ramkumar 2 , John Anton Michael 3 , Narasimhan Srinivasan4 , Bahavathi Ananthan Hemasathya 5
1-3 & 5 Department of Endodontics, Adhiparasakthi Dental College, and Hospital, Melmaruvathur 4 Hamad Dental center, Hamad medical corporation, Doha, Qatar
Address for Correspondence:
Dr.B.Hemasathya, M.D.S,
Department of Conservative Dentistry & Endodontics, Adhiparasakthi Dental College & Hospital, Melmaruvathur Phone no: 09841535787
Email id: hemasathya82@gmail.com
ABSTRACT
Background:
Extrusion of debris during root canal preparation into the periapical tissues, result in inflammation of the periodontal ligament. This may result in postoperative discomfort, flare-ups, or even apical healing failure, which could negatively impact the effectiveness of the endodontic therapy. This may result in postoperative discomfort, flare-ups, or even apical healing failure, which could negatively impact the effectiveness of the endodontic therapy. Aim and Objectives: This study compared the amount of debris extruded from the apex during apical preparation using a reciprocating file system versus a rotary file system.
Materials and Methods:
Twenty mandibular premolar teeth were divided into two groups at random. The root canals were created utilising rotary and reciprocating file systems in accordance with the manufacturer's specifications. During instrumentation, apically extruded material was gathered in preweighed tubes. The preweights and postweights of the tubes were subtracted to get the net weight of the apically extruded debris.
Results:
The statistical analysis was done with parametric techniques (Independent t test). Tukey multiple comparisons were used for post hoc pairwise comparisons. 0.05 was chosen as the alpha-type error value. A significant difference was discovered between the Protaper Universal (PTU) rotary system which extruded more debris than the Wave One Gold (WOG) reciprocating system.
Conclusion
WaveOne Gold extrudes less debris compared to ProTaper Universal file system. So according to this study Wave One Gold can be used without harm in the current clinical practice. Keywords: Root canal preparation, Nitinol, Periapical tissue, Freeze drying, Dental instrument.
Financial support and sponsorship
Nil
Conflicts of interest
There are no conflicts of interest.
How to cite: Ganesan K, Shanmugam R, John AM, Narasimhan S, Hemasathya B, Quantitative analysis of apically extruded debris between selective rotary and reciprocating files by lyophilisation & micro-balance. Int J Endodnd Rehabil Volume 2022, Article ID 22091315, 8 pages.